JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 1979; 58:288-292
© 1979 International Anesthesia Research Society
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tyler, D. C.
Right arrow Articles by Cheney, F. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tyler, D. C.
Right arrow Articles by Cheney, F. W.

Comparison of Positive End-Expiratory Pressure and Inspiratory Positive Pressure Plateau in Ventilation of Rabbits with Experimental Pulmonary Edema

Donald C. Tyler, MD*, and Frederick W. Cheney, MD{dagger}

*Assistant Professor of Anesthesiology and Pediatrics. Department of Anesthesiology, RN-10, University of Washington, Seattle, Washington 98195. {dagger}Professor of Anesthesiology. Department of Anesthesiology, RN-10, University of Washington, Seattle, Washington 98195.

Abstract

We investigated the effects of an inspiratory positive pressure plateau produced by a high (4/ 1) inspiratory-expiratory (I/E) ratio in rabbits with pulmonary edema induced with oleic acid. With an inspiratory pressure plateau, intrapulmonary shunt was significantly reduced compared to a standard 1 /2 I/E ratio. Reduction in shunt was also obtained when positive end-expiratory pressure (PEEP) was added to the 1 /2 I/E ratio ventilatory pattern. Since the improvement in shunt could have been caused by either recruitment of alveoli or by maintenance of lung volume at end exhalation we measured tidal volume and thoracic gas volume to distinguish between the two. With both patterns, improvement in shunt was associated with an increase in thoracic gas volume. The increase in thoracic gas volume was greater with PEEP than with 4/1 for an equivalent increase in mean airway pressure. The results suggest that an inspiratory pressure plateau improves gas exchange in pulmonary edema, but that this improvement occurs because of an increase in end-expiratory lung volume. Positive end-expiratory pressure is a preferable method of increasing end expiratory lung volume because a greater increase occurs for the same change in airway pressure.

Key Words: VENTILATION: positive end-expiratory pressure • VENTILATION: shunting • LUNG: edema







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 1979 by the International Anesthesia Research Society.