JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 1987; 66:529-532
© 1987 International Anesthesia Research Society
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Leiman, B. C.
Right arrow Articles by Butler, B. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Leiman, B. C.
Right arrow Articles by Butler, B. D.

Removal of Tracheal Secretions in Anesthetized Dogs

Balloon Catheters versus Suction

Basil C. Leiman, MB, BCh, Jeffrey Katz, MB, ChB, Theodore H. Stanley, MD, and Bruce D. Butler, PhD

Department of Anesthesiology, The University of Texas Medical School at Houston, Houston, Texas, and the Department of Anesthesiology, University of Utah College of Medicine, Salt Lake City, Utah.

Abstract

Artificial secretions were removed by suction (using 12– or 18-French suction catheters) or by means of a balloon-tipped catheter (6-French Fogarty® arterial embolectomy catheter) in 20 experiments performed on five dogs anesthetized with halothane. Each dog had 5 ml of mucin injected 10 cm down the endotracheal tube prior to a 30-sec period of intermittent positive pressure ventilation. After this procedure, the ventilator was disconnected and the secretions were removed by suction with the 12– or 18-French catheters or by the Fogarty catheter. Each dog had balloon removal performed twice and suction performed once with the 12-French and once with the 18-French catheter. The endotracheal tube was cleaned and a 15-min stabilization period was allowed between each experiment. Arterial blood pressure (MAP) and pulmonary artery pressure (PAP) did not change after either technique. There were no ECG changes, arrhythmias, or alterations in PaCO2. The PaO2 was significantly lower in the two suction catheter groups [520 ± 33 mm Hg (12 French) and 451 ± 31 mm Hg (18 French)] than in the balloon removal group (564 ± 10 mm Hg) (P < 0.05). The balloon technique removed more secretions (4.52 ± 0.06 ml) than did suction (12 French, 1.32 ± 0.17 ml; 18 French, 2.11 ± 0.44 ml). Balloon removal of tracheal secretions has two advantages over conventional suction techniques: it removes more secretions, and it has less detrimental effect on arterial oxygenation.

Key Words: LUNG—secretions







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press