JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 1988; 67:137-143
© 1988 International Anesthesia Research Society
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Abboud, T. K.
Right arrow Articles by Lee, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Abboud, T. K.
Right arrow Articles by Lee, J.

Mini-Dose Intrathecal Morphine for the Relief of Post-Cesarean SectionPain

Safety, Efficacy, and Ventilatory Responses to Carbon Dioxide

T. K. Abboud, MD, A. Dror, MD, P. Mosaad, MD, J. Zhu, MD, M. Mantilla, MD, F. Swart, MD, J. Gangolly, MD, P. Silao, MD, A. Makar, MD, J. Moore, MD, H. Davis, MD, and J. Lee, MD

Department of Anesthesiology, Los Angeles County-University of Southern California Medical Center, Los Angeles, California.

Abstract

To determine the safety, efficacy, and the ventilatory responses tocarbon dioxide (CO2) of mini-dose intrathecal morphine, 33 healthy women who underwent cesarean section with spinal anesthesia using 0.75% bupivacaine in 8.25% dextrose were studied. Patients were randomly assigned to receive, in a double-blind fashion, either morphine 0.25 mg (group I, n = 11), morphine 0.1 mg (group II, n = 10), or saline (group III, placebo group, n = 12) in 0.5 ml volume mixed with the bupivacaine.

In both groups I and II excellent postoperative analgesia with longduration was obtained (27.7 ± 4.0 and 18.6 ± 0.9 hours, respectively, X ± SEM). All patients in group III required an analgesic (8 mg subcutaneous morphine) within 3 hours of spinal anesthesia. Seven patients in group I and four patients in group II developed mild pruritus that did not require treatment. Ventilatory responses to CO2 showed no evidence of depression attributable to either the 0.25 or 0.1 mg of morphine, but significant depression of the CO2 responses was observed in group III patients after administration of subcutaneous morphine. It is concluded that a dose as low as 0.1 mg of intrathecal morphine gives excellent analgesia with minimal to no side effects and that subcutaneous morphine is associated with marked depression of the Ventilatory variables.

Key Words: ANALGESICS, MORPHINE—intrathecal. • PAIN—postoperative. • ANESTHESIA—obstetric. • ANESTHETIC TECHNIQUES, SPINAL—morphine.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
B. Carvalho
Respiratory Depression After Neuraxial Opioids in the Obstetric Setting
Anesth. Analg., September 1, 2008; 107(3): 956 - 961.
[Abstract] [Full Text] [PDF]


Home page
cfpHome page
P. Dopp
ITN requires training
Can Fam Physician, June 1, 2007; 53(6): 1003 - 1004.
[Full Text] [PDF]


Home page
Br J AnaesthHome page
C. Duale, C. Frey, F. Bolandard, A. Barriere, and P. Schoeffler
Epidural versus intrathecal morphine for postoperative analgesia after Caesarean section
Br. J. Anaesth., November 1, 2003; 91(5): 690 - 694.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
S. Ko, D. H. Goldstein, and E. G. VanDenKerkhof
Definitions of "respiratory depression" with intrathecal morphine postoperative analgesia: a review of the literature: [Definitions de la "depression respiratoire" de l'analgesie postoperatoire realisee avec de la morphine intrathecale : une revue documentaire]
Can J Anesth, August 1, 2003; 50(7): 679 - 688.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
D. M. A. Choi, A. P. Kliffer, and M. J. Douglas
Dextromethorphan and intrathecal morphine for analgesia after Caesarean section under spinal anaesthesia
Br. J. Anaesth., May 1, 2003; 90(5): 653 - 658.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
S.-A. Nortcliffe, J. Shah, and D. J. Buggy
Prevention of postoperative nausea and vomiting after spinal morphine for Caesarean section: comparison of cyclizine, dexamethasone and placebo
Br. J. Anaesth., May 1, 2003; 90(5): 665 - 670.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
J.-M. Devys, A. Mora, B. Plaud, C. Jayr, A. Laplanche, B. Raynard, P. Lasser, and B. Debaene
Intrathecal + PCA morphine improves analgesia during the first 24 hr after major abdominal surgery compared to PCA alone: [La morphine intrathecale + la morphine en AAC, comparee a la morphine en AAC seule, ameliore l'analgesie pendant les vingt-quatre premieres heures suivant une operation abdominale majeure]
Can J Anesth, April 1, 2003; 50(4): 355 - 361.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
C. M. Cowan, J. B. Kendall, P. M. Barclay, and R. G. Wilkes
Comparison of intrathecal fentanyl and diamorphine in addition to bupivacaine for Caesarean section under spinal anaesthesia
Br. J. Anaesth., September 1, 2002; 89(3): 452 - 458.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
J. Sarvela, P. Halonen, A. Soikkeli, and K. Korttila
A Double-Blinded, Randomized Comparison of Intrathecal and Epidural Morphine for Elective Cesarean Delivery
Anesth. Analg., August 1, 2002; 95(2): 436 - 440.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
T. Sakai, T. Fukano, and K. Sumikawa
IV butorphanol reduces analgesia but not pruritus or nausea associated with intrathecal morphine
Can J Anesth, September 1, 2001; 48(8): 831 - 832.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
X. Culebras, G. Gaggero, J. Zatloukal, C. Kern, and R.-A. Marti
Advantages of Intrathecal Nalbuphine, Compared with Intrathecal Morphine, After Cesarean Delivery: An Evaluation of Postoperative Analgesia and Adverse Effects
Anesth. Analg., September 1, 2000; 91(3): 601 - 605.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
C.-L. Shen, Y.-Y. Ho, Y.-C. Hung, and P.-L. Chen
Arrhythmias during spinal anesthesia for Cesarean section
Can J Anesth, May 1, 2000; 47(5): 393 - 397.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
K. H. Gwirtz, J. V. Young, R. S. Byers, C. Alley, K. Levin, S. G. Walker, and R. K. Stoelting
The Safety And Efficacy of Intrathecal Opioid Analgesia for Acute Postoperative Pain: Seven Years’ Experience with 5969 Surgical Patients at Indiana University Hospital
Anesth. Analg., March 1, 1999; 88(3): 599 - 599.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
J. C. Gerancher, H. Floyd, and J. Eisenach
Determination of an Effective Dose of Intrathecal Morphine for Pain Relief After Cesarean Delivery
Anesth. Analg., February 1, 1999; 88(2): 346 - 346.
[Abstract] [Full Text] [PDF]


Home page
J PsychopharmacolHome page
A. R. Wolf
Epidural opioids in the management of acute surgical pain
J Psychopharmacol, January 1, 1991; 5(4): 370 - 374.
[PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 1988 by the International Anesthesia Research Society.