JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 1988; 67:644-649
© 1988 International Anesthesia Research Society
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kumar, V.
Right arrow Articles by Jacob, A. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kumar, V.
Right arrow Articles by Jacob, A. M.

A Random Survey of Anesthesia Machines and Ancillary Monitors in 45 Hospitals

Viney Kumar, MD, Michael S. Hintze, and Arlene M. Jacob

This survey was conducted under Contract (223-85-4280) between the U.S. Food and Drug Administration and the Iowa Department of Public Health in collaboration with the Department of Anesthesia, University of Iowa College of Medicine.

Abstract

One hundred sixty-nine anesthesia machines and ancillary monitors were tested in 45 hospitals, randomly selected to assure a sample of hospitals with a wide range of anesthesia workload. The machines ranged in age from 1 to 28 years (8 ± 6, mean ± SD), with 47.3% manufactured since 1980, 39.1% between 1970 and 1980; and 13.6% before 1970. Regular maintenance was provided for 112 machines (66.2%) by the manufacturer, whereas 55 machines (32.5%) were maintained by independent contractors. Two machines designated as backup machines received no maintenance. There was no source of oxygen to back up oxygen piped from a central source on five machines. Thirteen machines had leaks over 500 ml/min distal to the common gas outlet, the most common sites being the carbon dioxide absorber, dome valves, and oxygen monitor sensor adaptors. Another two machines had leaks over 500 ml/min proximal to the common gas outlet. Forty-two of the 169 machines did not have an oxygen analyzer; another 18 had oxygen analyzers that did not function properly. Only 29 (23.5%) of 123 machines equipped with a ventilator had a working high-pressure alarm, whereas functioning low-pressure alarms were available on 104 machines (84.5%). Fourteen of the 383 vaporizers tested for calibration did not meet the calibration standard recommended by the manufacturers. None of the 32 liquid anesthetic samples collected and analyzed during the survey showed contaminants. Only four (8.8%) hospitals utilized a written anesthesia machine checklist. There was no correlation between the number of malfunctions observed and ages of the machines, although the older machines tended to lack the basic monitoring devices and safety features. Equipment inadequacies encountered during the survey period ranged in degree of severity. All such inadequacies were pointed out to the facilities involved. Those inadequacies considered to be major in nature have been rectified.

Key Words: EQUIPMENT, ANESTHESIA MACHINES—safety







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 1988 by the International Anesthesia Research Society.